internal ID number 0412 transmission ID number 2306 IMEI 300025010842400 transmission type IRIDIUM positioning system GPS instrument type APEXIR_TSO2 IRIDIUM program number 161149 WMO ID number 2902733 WMO instrument type (table 1770) 846 WMO recorder type (table 4770) 64 start time [dd mm yyyy hh mm (Z)] 25 11 2015 19 53 status of start time as recorded launch time [dd mm yyyy hh mm (Z)] 25 11 2015 20 30 status of launch time as recorded launch position [lat latm lon lonm] -50. 3.48 111. 31.8 status of launch position as recorded delay of first down time [hours] 6 down time [days] 9.542 up time [hours] 11 transmission repetition rate [sec] -999. clock drift [hours/hours] 0. last cycle n/a pressure activation piston position 16 park piston position 66 deep profile piston position 16 max air bladder pressure 124 ok vacuum threshold 96 piston full extenstion 227 ascent time out [hours] 9 deep profile descent time [hours] 5 park descent time [hours] 5 telemetry retry interval [min] 15 ice detection temperature [degC] -1.80 ice detection mixed layer pmax [dbar] 50 ice detection mixed layer pmin [dbar] 20 continuous profile activation [dbar] 985 ======================================== calib eq 1 for salinity sslope*cnts+soff calib coef for salinity SSLOPE=0.001; SOFF=0.0; calib eq 1 for temperature tslope*cnts+toff calib coef for temperature TSLOPE=0.001; TOFF=0.0; calib eq 1 for pressure pslope*cnts+poff calib coef for pressure PSLOPE=0.1; POFF=0.0; calib eq 1 for voltage vslope*cnts+voff calib coef for voltage VSLOPE=0.077; VOFF=0.486; calib eq 1 for current islope*cnts+ioff calib coef for current ISLOPE=4.052; IOFF=-3.606; calib eq 1 for vacuum vacslope*cnts+vacoff calib coef for vacuum VACSLOPE=0.293; VACOFF=-29.767; calib eq 1 for oxygen O2=[(c4+c5*T)/(c6+c7*TPHASE)-1]/[c1+c2*T+c3*T^2\]; O2c=O2 exp[ S (B0+B1.Ts+B2.Ts^2+B3.Ts^3) + C0.S^2];Ts=ln[(298.15-T)/(273.15+T)]; DO=O2c [1+ Pcoef * PRES/1000]; DOXY=DO/rho0 ;with T=TEMP, S=PSAL, rho0= potential density calib coef for oxygen c0=2.83641E-03;c1=1.20447E-04;c2=2.46665E-06;c3=2.30273E02;c4=-3.03652E-01;c5=-5.66982E01;c6=4.56033E00; ======================================== conductivity calibration date 17 10 2014 temperature calibration date 17 10 2014 pressure calibration date 13 10 2014 float manufacturer TWR float serial number 7510 program name CHINA ARGO EQUIVALENT PI YU ZHANG principal investigator address OUC, QINGDAO originating country CHINA float deployer YU ZHANG float deployer address OUC, QINGDAO deployment type R/V deployment platform N/A deployment cruise id ReMOCA profile at deployment n/a nominal drift pressure [dbar] 1000 cycles for drift pressure 1 nominal profile pressure [dbar] 2000 cycles for profile pressure 1 Profile Sampling Method continuous pump type 260ml conductivity sensor type SBE41CP_V2 conductivity sensor manufacturer SBE conductivity sensor serial number 6343 conductivity sensor accuracy 0.005 conductivity sensor resolution 0.001 temperature sensor type SBE41CP_V2 temperature sensor manufacturer SBE temperature sensor serial number 6343 temperature sensor accuracy 0.002 temperature sensor resolution 0.001 pressure sensor type 2900 PSIA pressure sensor manufacturer DRUCK pressure sensor serial number 4112794 pressure sensor accuracy 2.4 pressure sensor resolution 0.1 oxygen sensor type AANDERAA_OPTODE_4330 oxygen sensor manufacturer AANDERAA oxygen sensor serial number 1682 oxygen sensor accuracy 8 oxygen sensor resolution 1 battery type Alkaline initial battery voltage [volt] 15.0 ROM version 062813 Board serial number 12306 Board version APF-9i comment n/a